Agency / Source: Hitachi High Technologies America

Check Ads Availability|e-mail Article

Are you the owner of this article?, Turn it PREMIUM with your LOGO instead - and make it 3rd party Ads-Free! within the next hour!

Hitachi High Technologies Launches Sample Cleaner ZONESEM - The ZONESEM II Tabletop Sample Cleaner uses UV-based cleaning technology to minimize or eliminate hydrocarbon contamination for electron microscopy imaging - Hitachi-HTA.com
Hitachi High Technologies Launches Sample Cleaner ZONESEM

 

PRZOOM - /newswire/ - Pleasanton, CA, United States, 2019/03/13 - The ZONESEM II Tabletop Sample Cleaner uses UV-based cleaning technology to minimize or eliminate hydrocarbon contamination for electron microscopy imaging - Hitachi-HTA.com.

   
 
Your Banner Ad Here instead - Showing along with ALL Articles covering Electronics / Instrumentation / RFID Announcements

Replace these Affiliate Programs at ANYTIME! Your banner here within the next hour. Learn How!


 

Preparing, handling, or storing samples at atmospheric conditions may increase hydrocarbon build-up on the specimen, and under the influence of an electron beam these hydrocarbons can form a thick layer on the surface. Cleaning the sample surface with ZONESEMⅡ removes hydrocarbons and reduces available molecules for beam induced contamination. Preventing contamination from specimen surfaces is essential for true observation in electron microscopy.

ZONESEMⅡ utilizes vacuum-controlled UV irradiation and activated oxygen to gently remove hydrocarbons from the specimen surface prior to imaging and without the use of any chemicals or reagents. With a lab-friendly footprint and intuitive touch screen, the second-generation ZONESEMⅡ is a safe, easy-to-use addition to any laboratory.

Designed specifically for Hitachi specimen holders, the ZONESEMⅡ provides optimized sample cleaning and storage modes of operation. The ZONESEMⅡ serves as an excellent desiccator to prevent holder out-gassing.

• Easy-to-use touchscreen panel;
• Programmable up to 24hrs;
• Variable pressure control.

Cause of contamination
Interactions between hydrocarbons on the specimen surface and the irradiated electron beam generate sample contamination. Hydrocarbons are generally non-covalently attached to the specimen surface during sample handling, preparation, and storage.

Cleaning Process
The ZONESEMⅡ uses a UV lamp with wavelengths of 185 nm and 254 nm to efficiently remove hydrocarbons. Ozone is generated from oxygen in the vacuum-controlled specimen chamber, and generated ozone is broken into oxygen and activated oxygen. Hydrocarbons on the specimen surface are broken into volatile molecules such as CO2, H2O by radical oxygen and UV. The exhaust pump evacuates the free molecules from the sample chamber.

Specification
Description
Model No. - ZONE-2010
UV Lamp - Wavelengths: 184 nm, 254 nm (visible light, green and infrared light)
Specimen Size - 100 mm (D) × 37 mm (H)
Process Mode - UV Cleaning mode, Vacuum storage mode
Vacuum Setting - Settable by 100 phases of vacuum pressure
Process Setting - Time One minute to approximately 24 hours
Vacuum Pump - Dry vacuum exhaust system
Ozone exclusion - Built-in Ozone exclusion device
Unit - Dimension 310 mm (W) × 260 mm (D) × 305 mm (H)
Weight - 18 kg

Setting Condition
Description
Room Temperature - 15 - 30 degrees C
Humidity - ≤ 70% (no condensing dew)
Power Supply - Power Supply: AC100 V - 240 V (±10%), 50/60 Hz 0.14 kVA

 
 
Your Banner Ad Here instead - Showing along with ALL Articles covering Electronics / Instrumentation / RFID Announcements

Replace these Affiliate Programs at ANYTIME! Your banner here within the next hour. Learn How!


 

Agency / Source: Hitachi High Technologies America

 
 

Availability: All Regions (Including Int'l)

 

Traffic Booster: [/] Quick PRZOOM - Press & Newswire Visibility Checker

 

Distribution / Indexing: [+]  / [Company listed above is a registered member of our network. Content made possible by PRZOOM / PRTODAY indexing services]

 
 
# # #
 
 
  Your Banner Ad showing on ALL
Electronics / Instrumentation / RFID articles,
CATCH Visitors via Your Competitors Announcements!


Hitachi High Technologies Launches Sample Cleaner ZONESEM

Company website links NOT available to basic submissions
It is OK to republish and/or LINK any newswire for any legitimate media purpose as long as you name PRZOOM - Press & Newswire and LINK as the source.
 
  For more information, please visit:
Is this your article? Activate ALL web links by Upgrading to Press Release PREMIUM Plan Now!
ZONESEMⅡ | Hitachi High Technologies
Contact: Press Office - Hitachi-HTA.com 
co2[.]hitachi-hta.com
 
PRZOOM / PRTODAY - Newswire Today disclaims any content contained in this article. If you need/wish to contact the company who published the current release, you will need to contact them - NOT us. Issuers of articles are solely responsible for the accuracy of their content. Our complete disclaimer appears here.
IMPORTANT INFORMATION: Issuance, publication or distribution of this press release in certain jurisdictions could be subject to restrictions. The recipient of this press release is responsible for using this press release and the information herein in accordance with the applicable rules and regulations in the particular jurisdiction. This press release does not constitute an offer or an offering to acquire or subscribe for any Hitachi High Technologies America securities in any jurisdiction including any other companies listed or named in this release.

Electronics / Instrumentation / RFID via RSSAdd NewswireToday - PRZOOM Headline News to FeedBurner
Find who RetweetFollow @NewswireTODAY

Are you the owner of this article?, Turn it PREMIUM with your LOGO instead - and make it 3rd party Ads-Free! within the next hour!


Read Latest Press Releases From Hitachi High Technologies America / Company Profile


Read Electronics / Instrumentation / RFID Most Recent Related Press Releases:

ProMinent Unveils New DULCOEYE SAC Optical Sensor
Ezurio Cuts Ribbon on New U.S. Headquarters Rooted in a Legacy of Wireless Innovation
Murata Launches Common Mode Choke Coils with Metal Terminal Structure for Automotive CAN FD Supporting Maximum Operating Temperature of 150°C
ROHM’s New High Anti-Surge Chip Resistors SDR01 Series Achieve 0.33W Rated Power in the 0402 Size
Analog Devices to Acquire Alif Semiconductor, Adding an AI-Native Processing Platform to Advance Physical Intelligence for the Next Generation of Real
Infineon Extends Collaboration with SolarEdge to Enable Solid-state Protection for 800 VDC AI Data Centers
Baumer Group Granted the 2026 Global Position and Distance Sensors Company of the Year Recognition
Littelfuse Expands Omnipolar TMR Switch Family with Leaded TO-92 Package Option
TDK Launches Industry-leading Low-resistance Soft-termination X7R MLCCs with 10 ΜF/100 V in the 3225 Format for AI Servers, Humanoids, and XEVs
Imec Demonstrates the Extension of Chemically Amplified Resists for High NA EUV Lithography

Boost Your Social Network
& Crowdfunding Campaigns


LIFETIME SOCIAL MEDIA WALL
 
NewswireToday Celebrates 10 Years in Business
.



PREMIUM Members


Visit  RightITnow, Inc.

Visit  Limelon Advertising, Co.

Visit  La Bella Bakery Artisan Bakery Arizona







 
  ©2005-2026 PRZOOM - Limelon Advertising, Co.
Home | About PRZOOM | Advertise/Pricing | Contact | Investors | Privacy/TOS | Sitemap | FRANCAIS
newswire, PR press releases distribution service magazines engine news alert newsroom press room breaking news public relations articles company news alerts newswiredistribution ezine bizentrepreneur biznewstoday digital business report market search pr firms agencies reports distri-bution today investor relation successful internet entrepreneur newswire distribution prtoday.com freenewswiredistribution asianewstoday bizwiretoday USA pr UK today